Operating Temperature: 0 to 50°C; Operating Humidity: Less than 85%R.H. Circuit: Custom one-chip of microprocessor LSI circuit. Display: LCD size: 2.1x1.5in/52x38mm, LCD with green backlight (ON/OFF). Channels: T1, T2, T3, T4, T1-T2. Sensor type: Type K thermocouple probe, Type J/T/E/R/S thermocouple probe, PT 100ohm probe. Cooperate with 0.00385 alpha coefficient, meet DIN IEC 751. Resolution: 0.1°C/1°C, 0.1°F/1°F, Interface: RS-232, USB via interface converter, Bluetooth
AKTAKOM ATE-2036BT is a 4 channels thermometer with real time SD memory card datalogger with Bluetooth interface. Bluetooth interface provides wireless connection for data displaying and logging on a PC (Windows OS) and any mobile device containing this interface (Android OS).
Features
Type K/J/T/E/R/S, Pt 100ohm, measurement with 4 displays
Shows 4 channels on the LCD at the one time
Type K: -148 to 2372°F / -100 to 1300°C
Type J: -148 to 2192°F / -100 to 1200°C
Pt 100ohm: -327.82 to 1562°F / -199.9 to 850.0°C
°C/°F, 0.1 degree / 1 degree
4 channels (T1, T2, T3, T4), T1-T2
Microcomputer circuit provides intelligent function and high accuracy
Offset adjustment for the Type K/J/T/E/R/S measurement
Offset adjustment for the Pt 100 measurement
Measuring unit can select to °C or °F
Real time SD memory card Datalogger, Built-in Clock and Calendar, real time data recorder, sampling time set from 1 second to 3600 seconds
Manual datalogger is available (set the sampling time to 0), during the use of manual datalogger function it can set the different position (location) No. (position 1 to position 99)
Innovation and easy operation, computer doesn’t need any extra software, after the datalogger use just take the SD card away from the meter and plug in the SD card into the computer, it can download all of the measured value with the time information (year/month/date/hour/minute/second) to the Excel directly; then users can make the further data or graphic analysis by themselves
SD card capacity: 1 GB to 16 GB
LCD with green light backlight, easy reading
Can default auto power off or manual power off
Data hold, record max. and min. reading
Microcomputer circuit, high accuracy
Power by UM3/AA (1.5V) x 6 batteries or DC 9V adapter
Interface: RS-232, USB via interface converter, Bluetooth
Heavy duty & compact housing case
Specifications
General Specifications:
Circuit: Custom one-chip of microprocessor LSI circuit
Display:
LCD size: 2.1x1.5in/52x38mm
LCD with green backlight (ON/OFF)
Channels: T1, T2, T3, T4, T1-T2
Sensor type:
Type K thermocouple probe
Type J/T/E/R/S thermocouple probe
PT 100ohm probe
Cooperate with 0.00385 alpha coefficient, meet DIN IEC 751
Resolution: 0.1°C/1°C, 0.1°F/1°F
Datalogger / Sampling Time / Setting range:
Auto:
1 second to 3600 seconds
Sampling time can set to 1 second but memory data may loss
Manual:
Push the data logger button once will save data one time
Set the sampling time to 0 second
Manual mode, can also select the 1 to 99 position (Location) no.
Memory Card: SD memory card. 1 GB to 16 GB
Advanced setting:
Set clock time (Year/Month/Date, Hour/Minute/ Second)
Decimal point of SD card setting
Auto power OFF management
Set beep Sound ON/OFF
Set temperature unit to °C or °F
Set sampling time
SD memory card Format
Temperature Compensation: Automatic temp. compensation for the type K/J/T/E/R/S thermometer
Linear Compensation: Linear Compensation for the full range
Offset Adjustment: Available for Type K/J/T/E/R/S and Pt 100ohm
Probe Input Socket:
Type K/J/T/E/R/S 2 pin thermocouple socket
Pt 100ohm: Ear phone socket
Over Indication: Show " _ _ _ _ "
Data Hold: Freeze the display reading
Memory Recall: Maximum & Minimum value
Sampling Time of Display: Approx. 1 second
Data Output:
RS-232 serial interface capable of PC connection via USB with Aktakom ACE-1025 interface converter and wide data processing capabilities with ADLM-W software or ASDM and ASDL applications Windows and Android based respectively.
Power off: Auto shut off saves battery life or manual off by push button
Operating Temperature: 0 to 50°C
Operating Humidity: Less than 85%R.H.
Power Supply:
Alkaline or heavy duty DC 1.5 V battery (UM3, AA) x 6 PCs, or equivalent
ADC 9V adapter input. (AC/DC power adapter is optional)
Power Current:
Normal operation (w/o SD card save data and LCD Backlight is OFF): Approx. DC 8.5mA
When SD card save the data and LCD Backlight is OFF): Approx. DC 30mA
If LCD backlight is on the power consumption will increase approx. 14mA
Electrical Specifications (23±5°C):
PT 100 ohm
Resolution
Range
Accuracy
0.1°C
-199.9 to 850.0°C
± (0.4%+1°C)
0.1°F
-327.0 to 999.9°F
±(0.4%+1.8°F)
1°F
1000 to 1562°F
±(0.4%+2°F)
Pt 100ohm probe TP-101 is the optional accessory
Type K/J/T/E/R/S:
Sensor Type
Resolution
Range
Accuracy
Type K
0.1°C
-50.1 to -100.0°C
±(0.4%+1°C)
-50.0 to 999.9°C
±(0.4%+0.5°C)
1°C
1000 to 1300°C
±(0.4%+1°C)
0.1°F
-58.1 to -148.0°F
±(0.4%+1.8°F)
-58.0 to 999.9°F
±(0.4%+1°F)
1°F
1000 to 2372°F
±(0.4%+2°F)
Type J
0.1°C
-50.1 to -100.0°C
±(0.4%+1°C)
-50.0 to 999.9°C
±(0.4%+0.5°C)
1°C
1000 to 1150°C
±(0.4%+1°C)
0.1°F
-58.1 to -148.0°F
±(0.4%+1.8°F)
-58.0 to 999.9°F
±(0.4%+1°F)
1°F
1000 to 2102°F
±(0.4%+2°F)
Type T
0.1°C
-50.1 to -100.0°C
±(0.4%+1°C)
-50.0 to 400.0°C
±(0.4%+0.5°C)
0.1°F
-58.1 to -148.0°F
±(0.4%+1.8°F)
-58.0 to 752.0°F
±(0.4%+1°F)
Type E
0.1°C
-50.1 to -100.0°C
±(0.4%+1°C)
-50.0 to 900.0°C
±(0.4%+0.5°C)
0.1°F
-58.1 to -148.0°F
±(0.4%+1.8°F)
-58.0 to 999.9°F
±(0.4%+1°F)
1°F
1000 to 1652°F
±(0.4%+2°F)
Type R
1°C
0 to 600°C
±(0.5%+1°C)
601 to 1700°C
±(0.5%+1°C)
1°F
32 to 1112°F
±(0.5%+2°F)
1113 to 3092°F
±(0.5%+2°F)
Type S
1°C
0 to 600°C
±(0.5%+1°C)
601 to 1500°C
±(0.5%+1°C)
1°F
32 to 1112°F
±(0.5%+2°F)
1113 to 2732°F
±(0.5%+2°F)
Remark:
a. Accuracy value is specified for the meter only
b. Accuracy is tested under the meter environment temperature within 23±5°C
c. Linearity Correction: memorizes the thermocouple curve into the intelligent CPU circuit
Above specification tests under the environment RF Field Strength less than 3 V/M & frequency less than 30MHz only
All the measuring procedures are same as the Type K except to select the Temp. Sensor type to "Pt" by pressing the "Type Button" (3-5, Fig. 1) once in sequence until the right down LCD display show "Pt" text as:
Insert the Pt 100 ohm probe (optional, PT-101) to
PT1 input socket (3-10, Fig. 1)
PT2 input socket (3-11, Fig. 1)
* The Pt 100 ohm measurement only allow max. two channels (two probes) input.
T1-T2 measurement
If the meter already insert two probes:
Type K/J/T/E/R/S: T1, T2 input socket
Pt 100 ohm: PT1, PT2 input socket
Pressing the "T1-T2 button" (3-6, Fig. 1), display will show the difference temperature value between T1, T2 (PT1, PT2) as:
Type J/T/E/R/S measurement
All the measuring procedures are same as the Type K except to select the Temp. Sensor type to "Type J/K/T/E/R/S" by pressing the "Type Button" (3-5, Fig. 1) once in sequence until the up LCD display show "J/T/E/R/S" indicator.
Type K measurement
Power on the meter by pressing the "Power" (3-2, Fig. 1) button once. When the meter is already on pressing "Power" button once (>2s) will turn off the meter
Meter default Temp. sensor type is Type K, the display will show "K" indicator
The default temperature unit is °C (°F)
Insert the Type K probes into the "T1, T2, T3, T4 input socket" (3-9, Fig. 1).
The LCD will show the 4 channels (T1, T2, T3, T4) of temperature value at the same time. If the certain channels do not insert the temperature probes the relative channel display will show over range "- - - - -".
3-1 Display
3-2 Power Button (ESC, Backlight Button)
3-3 Hold Button (Next Button)
3-4 REC Button (Enter Button)
3-5 Type Button (▲ Button, L Button)
3-6 T1-T2 Button (▼ Button, R Button)
3-7 SET Button (Time check Button)
3-8 Logger Button (OFFSET Button, Sampling time check Button)
3-9 T1,T2,T3,T4 input socket (Type K, Type J)
3-10 PT1 input socket (Pt 100 ohm)
3-11 PT2 input socket (Pt 100 ohm)
3-12 RS-232 output terminal
3-13 DC 9V adapter socket
3-14 Tripod Fix Nut
3-15 Battery Cover Screws
3-16 Battery compartment/Cover
3-17 Stand
3-18 SD card socket
Can I using Aktakom Data Logger Monitor (ADLM-W) software load all of the information from the memory card to plot a graph?
The environment meter records data to the memory card in *.xls format. All of the data can be copied to the PC after the measurement process.
Aktakom Data Logger Monitor (ADLM-W) software can be used for the measurement data transmission (using Aktakom ACE-1025 interface converter) that means for online monitoring only.
AKTAKOM ATE Easy Monitor software provides the numerical indication of 4 channel measurements as well as the data recording into file in CSV format. For the device connection the use of ACE-1025/ACE-1026 USB-RS232 interface converters is required.
ADLM-A software is designed for data reading from devices of AKTAKOM ATT, ATE series, for measurement data acquisition, its processing, displaying and storage in a tablet PC with Android OS of 4.0 and more advanced versions.
ADLM-w software is designed for data reading from devices of AKTAKOM ATT, ATE series, for measurement data acquisition, its processing, displaying and storage in a PC with Windows XP x32, Windows 7 x64, Windows 7x32, Windows 8 x64, Windows Vista OS.
Aktakom Smart Data Logger (ASDL) software is designed for data reading received from AKTAKOM ATT and ATE series devices, measurement data acquisition, its processing, displaying, including graphs, and saving to a mobile device with Android 4.0 or more advanced OS version.
Aktakom Smart Data Monitor (ASDM) software is designed for the connection to AKTAKOM ATT and ATE series via Bluetooth interface, for measurement data acquisition, its displaying and saving to a mobile device with Android 4.0 or newer OS.