ATA-2504 Clamp Meter

Clamp meter-adapter. Three ranges (4 A, 40 A, 200 A) in every measurement mode (AC/DC). Output signal: from 1 to 100 mV, 1 A (AC/DC). Frequency range: 40 Hz...1 kHz. Hall effect sensor. Dimensions: 7.2 x 2.4 x 1.4 in / 183 x 61 x 36 mm. Weight: 6.7 oz / 190 g.

AKTAKOM ATA-2504 is a clamp meter-adapter. If you connect it to a multimeter the measurement results will be displayed on the display of this multimeter. In case of connecting ATA-2504 to an oscilloscope you will be able of researching a signal waveform.

Specifications:

  • Three ranges (4 A, 40 A, 200 A) in every measurement mode (AC/DC)
  • Output signal: from 1 to 100 mV, 1 A (AC/DC)
  • Frequency range: 40 Hz...1 kHz
  • Hall effect sensor
  • 2 batteries: 1.5V, AA-type
  • Dimensions: 7.2 x 2.4 x 1.4 in / 183 x 61 x 36 mm
  • Weight: 6.7 oz / 190 g

Direct current

RangeOutputAccuracySensitivity
0...4 A*100 mV/A±(0.02 + 0,005 A)0.1 mV/1 mA
0...40 A10 mV/A±(0.01 + 0,02 A)0.1 mV/10 mA
0...150 A1 mV/A±(0.01 + 0,2 A)0.1 mV/100 mA
150...200 A1 mV/A±(0.022 + 0,2 A)0.1 mV/100 mA

* at the range of 4 A the output voltage can vary within 0.4 mV

Alternating current (with 40 Hz...1 kHz frequency)

RangeOutputAccuracySensitivity
0...4 A100 mV/A±(0.02 + 0.005 A)0.1 mV/1 mA
0...40 A10 mV/A±(0.015 + 0.03 A)0.1 mV/10 mA
0...150 A1 mV/A±(0.015 + 0.3 A)0.1 mV/100 mA
150...200 A1 mV/A±(0.022 + 0.2 A)0.1 mV/100 mA

Accessories:

  • Measurement probes
  • Varrying case
  • User manual