Search
Log in
Login:
Password:
Register
Forgot your password?

ATK-2103 Clamp Meter

2 in 1: clamp meter + digital multimeter. True RMS reading for ACV & ACA measurement. 4000 counts, Auto range, multi-functions for ACA, DCA, ACV, DCV, Ohms, Capacitance, Hz, Duty cycle, diode and continuity test. Wide ranges (2000A, 400 A) clamp on current measurement both for ACA and DCA. 4 ranges (400 µA, 4000 µA, 40 mA, 400 mA) direct current input measurement both for ACA and DCA. Dimensions: 0 x 2.9 x 1.5 in / 255 x 73 x 38 mm. Weight: 0.85 lb / 380 g.

AKTAKOM ATK-2103 contains 2 devices in one housing! There is multimeter and clamp meter! ATK-2103 is capable of measuring up to 8 electric quantities, continuity testing. Big diameter of clamp meter jaws allows you to measure current in flat wires 2.4 in / 60 mm wide as well as round wires with 2 in / 50 mm diameter.

Features:

  • 2 in 1, 2000 A clamp meter + Digital multimeter
  • True RMS reading for ACV & ACA measurement
  • 4000 counts, Auto range, multi-functions for ACA, DCA, ACV, DCV, Ohms, Capacitance, Hz, Duty cycle, diode and continuity test
  • Wide ranges (2000A, 400 A) clamp on current measurement both for ACA and DCA
  • 4 ranges (400 µA, 4000 µA, 40 mA, 400 mA) direct current input measurement both for ACA and DCA
  • LSI circuit provides high reliability and durability
  • Overload protection circuit is provided for all ranges
  • Data hold
  • Backlight

Specifications:

General specifications:

  • Display: 0.6 in / 15 mm, 4 digit LCD, max. indication: 4000
  • Measurement range: ACA, DCA, ACV, DCV, Ohms, Capacitance, Hz, Duty cycle, diode and continuity test
  • Polarity: Automatic switching
  • Current Sensor: Hall effect sensor
  • Over-input: Indication of "1" or "-1"
  • Sampling time: 0.35 sec. approx.
  • Battery: DC 9V battery, heavy duty or Alkaline type, 006P, MN1604 ( PP3) or equivalent
  • Power consumption: approx. DC 5 mA
  • Operating temperature: 32°F to 122°F / 0°C to 50°C
  • Operating humidity: less than 80% RH
  • Dimensions: 10 x 2.9 x 1.5 in / 255 x 73 x 38 mm
  • Weight: 0.85 lb / 380 g

Electrical Specifications:

Function Range Resolution Accuracy Overload protection
DC/AC voltage 400 mV (DC only) 0.1 mV ±( 0.5 % + 2d ) AC/DC 1000 V
4 V 0.001 V DCV: ±(1 % + 2d)
ACV: (1.2 % + 5d)
40 V 0.01 V
400 V 0.1 V
1000 V 1 V
DC/AC current (direct input) 400 µA 0.1 µA ±(1.2% + 5d) AC/DC 500 mA (fuse)
4000 µA 1 µA
40 mA 0.01 mA
400 mA 0.1 mA
DC/AC current (clamp on) 400 A 0.1 A ±(2 % + 5 d) AC/DC2000A/1000V
2000 A 1 A ±(2 % + 8 d)
Note: · True rms measurement both for ACV, ACA function · Input impedance for ACV and DCV range is 10 MΩ · ACA, ACV frequency response is from 45 to 1 KHz · ACA, ACV specification be tested on sine wave 50/60 Hz.
Ohms 400 Ω 0.1 Ω ±(1 % + 5 d) AC / DC 400V
4 kΩ 1 Ω
40 kΩ 10 Ω
400 kΩ 100 Ω
4 MΩ 1 kΩ ±(2 % + 2 d)
40 MΩ 10 kΩ ±(3.5 % + 5d)
Capacitance 50 nF 10 pF ±(3 % + 5d) AC / DC 400V

500 nF 100 pF

5 µF 0.001 µF

50 µF 0.01 µF
Frequency (>5 V) 5 Hz 0.001 Hz ±(1 % + 5 d) AC / DC 1000V

50 Hz 0.01 Hz

500 Hz 0.1Hz

5 kHz 1 Hz

50 kHz 0.01 kHz

100 kHz 0.1 kHz
Duty cycle 1 % to 99% 0.1 %
Diode Short/non conductance, good/defect test

Accessories:

  • Test leads
  • User manual

Back to the section
AKTAKOM - the Best in Test Award Winner!