AM-1060 Digital Multimeter

Handheld digital multimeter. Measurement: DCV, ACV, DCA, ACA, Resistance, Capacitance, Frequency, Temperature, Diode, Continuity beeper. A/D counts no.: 4000 counts. Range selection: auto range with manual range selecting. Zero adjustment: automatic. Sampling time: approx. 0.5 to 1 second. Operating temperature: 0°C to 50°C (32°F to 122°F). Operating humidity: Max. 80%RH. Power supply: 1.5V battery x 2 PCs UM-4/AAA/Micro/R03 type. Power consumption: approx. DC 2.5mA

Manuals: 
User's Manual (2.2 Mb)

AKTAKOM AM-1060 digital multimeter provides multi function measurement: DCV, ACV, DCA, ACA, Resistance, Capacitance, Frequency, Temperature, Diode, Continuity beeper.

Features:

  • Meet IEC 1010 CATIII 1000V
  • Large LCD display with bar graph indication and frequency measurement path
  • Max./Min., Peak value, Relative, Data hold
  • Auto range with manual range selection
  • °C/°F thermometer
  • VAHz button, when execute the ACV, ACA function also can measure the frequency of signal
  • 4000 counts A/D, high resolution
  • Built-in fuse for both 10A, mA, uA current range
  • 10Mohm input impedance for voltage circuit
  • Full line optional adapters

Specifications

Function Range Resolution Accuracy
DC Voltage
400mV 0.1mV ±(0.5%reading+2digits)
4V 0.001V ±(0.8%reading+1digits)
40V 0.01V
400V 0.1V
1000V 1V
AC Voltage (50/60Hz) 400mV 0.1mV ±(1.0%reading+2digits)
4V 0.001V
40V 0.01V
400V 0.1V
1000V 1V
DC Current
400uA 0.1uA ±(1.5%reading+2digits)
4000uA 1uA
40mA 0.01mA ±(1.0%reading+2digits)
400mA 0.1mA ±(1.5%reading+2digits)
10A 0.01A ±(1.0%reading+2digits)
AC Current (50/60Hz) 400uA 0.1uA ±(1.5%reading+2digits)
4000uA 1uA
40mA 0.01mA ±(1.0%reading+2digits)
400mA 0.1mA ±(1.5%reading+2digits)
10A 0.01A ±(1.0%reading+2digits)
Resistance 400Ω 0.1Ω ±(1.0%reading+2digits)
4kΩ ±(1.5%reading+2digits)
40kΩ 10Ω
400kΩ 100Ω
4MΩ 1kΩ
40MΩ 10kΩ ±(3.0%reading+5digits)
Continuity buzzer: <20Ω ; Max Voltage 500V (DC) / 250V (AC rms)
Capacitance 4nF
0.001nF

±(3.0%reading+1digits)
40nF
0.01nF
400nF
0.1nF
4uF 0.001uF
40uF
0.01uF
400uF 0.1uF
4mF 0.001mF ±(4.0%reading+1digits)
40mF 0.01mF ±(12.0%reading+1digits)
Frequency (response 1.5V...5V)
4kHz
0.001kHz ±(0.5%reading+2digits)
40kHz 0.01kHz
400kHz 0.1kHz
4MHz 1kHz
40MHz 10kHz
Temperature
(K-type)
-20°C...300°C 1°C ±(1.0%reading+2digits)
301°C...750°C 1°C ±(3.0%reading)

General specifications

Display: 2.6x2in/65x48mm large LCD (4000 counts) display with bar graph indication and frequency measurement path
Range selection: Auto range with manual range selecting
Data hold: To freeze the display reading on the LCD display
Auto Power Off: this function can be disabled.
Memory recall: Records Maximum & Minimum readings with recall
Peak value: To measure the signal peak value (>1ms)
Relative measurement: To offset the measurement value
Polarity: Automatic Switching, "-" indicates negative polarity
Zero adjustment: Automatic
Sampling time: Approx. 0.5 to 1 second
Input impedance: 10Mohm.
Operating temperature: 0°C to 50°C (32°F to 122°F)
Operating humidity: Max. 80%RH.
Power supply: 1.5V battery x 2 PCs UM-4/AAA/Micro/R03 type
Power consumption: Approx. DC 1.7mA
Dimensions: 7.3x3.5x1.6in/185x88x40mm
Weight: 0.77lb/350g

Standard accessories

  • Red and Black Test Lead
  • 0.5 Amp Spare Fuse
  • User Manual

Optional accessories

  • Full line adapters: ACA/DCA current adapter, adapter, Tachometer adapter, Humidity adapter, Pressure adapter, Light adapter, EMF adapter, Sound level adapter, High voltage probe
  • Soft carrying case
  • Temperature probe

DMM basic measurement functions

As an example: oscilloscope diagnostic board AKTAKOM AEE-1017-V1 testing modes are given.


AC/DC Voltage (parallel connection to the circuit)

& Current (serial! connection to the break in circuit)

e.g.: sine output (3V/5kHz)


AC Voltage Line Frequency ("Hz" button)

e.g.: "FM" output (5kHz)

Resistance measurement

e.g.: 4.5 kOhm resistor

Capacitance

e.g.: SMD capacitor

Frequency (logic)

e.g.: Counter impulse frequency

Continuity (sound buzzer)

e.g.: between different "ground" points of the circuit

Temperature (K type probe)

e.g.: micro-chip surface temperature

Relative measurements (offset)

e.g.: leads resistance compensation

Diode test

e.g.: diode forward and backward Voltage drop


Frequently Asked Questions

  • How DMM is designed (disassembled view)
  • How to replace or install the batteries?
  • Does AKTAKOM AM-1060 multimeter have auto power off function?
  • How can I deactivate Auto Power Off function of AKTAKOM AM-1060 multimeter?

  • How DMM is designed (disassembled view)

    Front panel covers LCD, button board, rotary function switch gear and main plated circuit board:

    *Rubber strip between the back and front chassis covers protects from water and dust.

    Protective fuses are mounted near the inputs and sound buzzer is placed behind the LCD.

    *There is also an extra fuse fixed at the buttom (for several models)
    Up

    How to replace or install the batteries?

    When the batteries become exhausted or drop below the operating voltage, “BAT” indicator will appear in the LCD display. In this case the battery should be replaced, however in-spec. measurements may still be made for several hours after "Low battery indicator" appears before the instrument become inaccurate.

    WARNING! To avoid electric shock, disconnect the test leads from any source of voltage before removing the battery cover.

    "DC 9V" type 006 P (e.g. AMM-1061)

    1. Open the battery cover by loosing the screws with the cross-point screwdriver

    2. Carefully disconnect the old battery

    3. Connect the new battery of the proper type to the power leads

    4. Close the battery cover and reinstate the cover

    "DC 1.5V" type AAA (e.g. AMM-1060)

    1. Open the battery cover by loosing the screws with the cross-point screwdriver

    2. Carefully pull out the buttery carrier and take off the old batteries

    3. Plug the new batteries of the proper type in the holder and put it back

    4.Close the battery cover and reinstate the cover

    After completion make sure you don’t have any spare parts

    If you do find spare parts, you must start all over


    Up

    Does AKTAKOM AM-1060 multimeter have auto power off function?

    Yes, it does. There is Auto Power Off function in AM-1060: the device power automatically goes off if you do not use the device within 15 minutes. 30 seconds before the device powers off it will make 3 short sound signals and before powering off – one more long signal. To start the operation again press any button or use the rotary switch.


    Up

    How can I deactivate Auto Power Off function of AKTAKOM AM-1060 multimeter?

    To deactivate Auto Power Off function press RS232 button.


    Up

    Designing Off Delay Timer Switch for Water Pump Control

    Electrical Engineer Shows You How to Fix Your Pool Electrical Supply

    LED Repair Tutorial Part 5

    How to Use a Digital Multimeter to Test LED Chips

    LED Repair Tutorial Part 4

    Fixing LED Light Fixture Part 3: Unforeseen causes of broken LED lights

    LED Light Driver Repair and Redesign using AKTAKOM AM-1060 DMM

    Useful Features of the AKTAKOM AM-1060 Multimeter

    How to fix LED light fixture using AKTAKOM AM-1060 DMM, ASE-1209 Soldering Tweezers and APS-7306 Power Supply

    How to Use AM-1060 Multifunctional Multimeter


    Back to the section