ATE-9382 Humidity/Baro/Temp. Monitor

Humidity: Range: 10 % to 90 % R.H., Resolution: 0.1 % R.H., Accuracy: ≥70% RH: ± (4% reading + 1% RH), < 70% RH: ± 4% RH; Temperature: Range: 32°F to 122°F / 0°C to 50°C, 0.1 degree, Resolution: 0.1 degree; Accuracy: 0.8 °C, 1.5 °F. Interface: RS-232, USB via interface converter

Manuals: 
User's Manual (596.15 Kb)

AKTAKOM ATE-9382 is a monitor with real time datalogger which saves the measuring data along the time information (year, month, date, hour, minute, second) into the SD memory card and can be downloaded to the Excel without any extra software, users can make the further data or graphic analysis by themselves.

Features:

  • Shows Humidity, Temperature and Barometer value in the same LCD
  • %RH resolution for the humidity reading, 0.1 degree resolution for the Temp. reading
  • The precision capacitance type humidity sensor is used, professional and high accuracy for humidity measurement
  • Professional barometer: hPa, mmHg, inHg
  • SD card capacity: 1 GB to 16 GB
  • Large LCD display, easy readout
  • Microcomputer circuit, high reliability
  • The circuit design are deigned to consider low power consumption and long battery life when use battery power
  • DC 1.5V (UM-4, AAA) battery x 6 PCs or DC 9V adapter
  • Interface: RS-232, USB via interface converter
  • Patented

Specifications:

General Specifications:

Circuit: Custom one-chip of microprocessor LSI circuit

Display: LCD size: 2.4in x 2in / 60mm x 50mm

Measurement: Humidity, Temperature and Barometer

Memory Card: SD memory card, 1 GB to 16 GB

Datalogger / Sampling Time:

5/10/30/60/120/300/600 seconds or Auto.

  • Default sampling time is 60 seconds.
  • The " Auto " sampling means when the measuring value is changed ( >± 1 %RH or > ± 1 °C or > ± 1 hPa ) will save the data one time only

Data error no.: ≦ 0.1 % no. of total saved data typically

Advanced settings:

  • SD memory card Format
  • Set clock time (Year/Month/Date, Hour/Minute/Second)
  • Set sampling time
  • Set beeper sound ON/OFF
  • Decimal point of SD card setting
  • Set temperature unit to °C or °F
  • Set RS232 out ON/OFF.
  • Set the unit of Barometer

Update Time of Display: Approx. 1 second if measuring data is changed

Data Output:

RS-232 serial interface capable of PC connection via USB with Aktakom ACE-1025 interface converter and wide data processing capabilities with ADLM-W software or ASDM and ASDL applications Windows and Android based respectively.

Operating temperature: 0 to 50 °C

Operating humidity: Less than 90% R.H

Power supply:

  • Alkaline or heavy duty DC 1.5 V battery (UM4, AAA) x 6 PCs, or equivalent
  • DC 9V adapter input (AC/DC power adapter is optional)

Battery life: If you use a new battery (alkaline type) and sampling time is set to 60 seconds the battery life will be typically more than one month

Electrical specifications (23±5 °C):

Humidity:

Range: 10 % to 90 % R.H.

Resolution: 0.1 % R.H.

Accuracy:

  • ≥70% RH: ± ( 4% reading + 1% RH)
  • < 70% RH: ± 4% RH

Temperature:

Range: 32°F to 122°F / 0°C to 50°C

Resolution: 0.1 degree

Accuracy:

°C - 0.8 °C

°F - 1.5 °F

Barometer:

Measurement Range Resolution Accuracy
hPa 10.0 to 1000.0

1001 to 1100
0.1

1
± 2 hPa 1 ± 3 hPa
mmHg 7.5 to 825.0 0.1 ± 1.5 mmHg
inHg 0.29 to 32.48 0.01 ± 0.1 inHg

Weight: 0.63lb / 285g

Dimensions: 5.2in x 3.1in x 1.3in / 132mm x 80mm x 32mm

General accessories:

  • Instruction manual.
  • Hanging unit (with sticker)

Optional accessories:

  • SD Card (2 GB)
  • AC to DC 9V adapter
  • USB cable, USB-01
  • RS232 cable, UPCB-02
  • Data Acquisition software, SW-U801-WIN

Frequently Asked Questions

  • Can I using Aktakom Data Logger Monitor (ADLM-W) software load all of the information from the memory card to plot a graph?

  • Can I using Aktakom Data Logger Monitor (ADLM-W) software load all of the information from the memory card to plot a graph?

    The environment meter records data to the memory card in *.xls format. All of the data can be copied to the PC after the measurement process.

    Aktakom Data Logger Monitor (ADLM-W) software can be used for the measurement data transmission (using Aktakom ACE-1025 interface converter) that means for online monitoring only.


    Up

    Compatible Software


    Aktakom ATE Easy Monitor (ATEE Monitor)
    AKTAKOM ATE Easy Monitor software provides the numerical indication of 4 channel measurements as well as the data recording into file in CSV format. For the device connection the use of ACE-1025/ACE-1026 USB-RS232 interface converters is required.
    Aktakom Data Logger Monitor (ADLM-A)
    ADLM-A software is designed for data reading from devices of AKTAKOM ATT, ATE series, for measurement data acquisition, its processing, displaying and storage in a tablet PC with Android OS of 4.0 and more advanced versions.
    Aktakom Data Logger Monitor (ADLM-W)
    ADLM-w software is designed for data reading from devices of AKTAKOM ATT, ATE series, for measurement data acquisition, its processing, displaying and storage in a PC with Windows XP x32, Windows 7 x64, Windows 7x32, Windows 8 x64, Windows Vista OS.

    Back to the section