High performance Aktakom AMM-1037 digital multimeter is capable of measuring DCV, ACV, DCA, ACA, resistance, capacitance, frequency as well as diode and continuity test.
	AMM-1037 uses dual-integral A/D converter as key point.
Features: 
	- 
	LCD display with a backlight, 19999(41/2), auto polarity indication 
 
	- 
	Measuring method: dual slope A/D transfer 
 
	- 
	Sampling rate: approx. 3 times/sec 
 
	- 
	Over range indication: “OL” or ”-OL” should be displayed 
 
	- 
	Low battery indication 
 
	- 
	Operation environment: 0~40℃, 
 
	- 
	Relative humidity: <80% 
 
	- 
	Power: one 9V battery 
 
	- 
	Dimensions: 7.5 x 3.5 x 1.1 in / 190 x 88.5 x 27.5 mm 
 
	- 
	Weight: approx. 14.9 oz / 422g (including battery) 
 
Technical specifications: 
DCV 
	| 
		 Range
	 | 
	
		 Accuracy
	 | 
	
		 Resolution
	 | 
	| 
		 200mV
	 | 
	
		 ±(0.1%+5)
	 | 
	
		 0.01mV
	 | 
	| 
		 2V
	 | 
	
		 0.0001V
	 | 
	| 
		 20V
	 | 
	
		 0.001V
	 | 
	| 
		 200V
	 | 
	
		 0.01V
	 | 
	| 
		 1000V
	 | 
	
		 ±(0.2%+5)
	 | 
	
		 0.1V
	 | 
	 Input impedance: 
	 200mV range: 1MΩ 
	 other ranges: 10MΩ;
	 Overload protection: 
	 200mV range: DC 250V or AC peak value.
	 Other ranges: DC 1000V or AC peak value
ACV 
	| 
		 Range
	 | 
	
		 Accuracy
	 | 
	
		 Resolution
	 | 
	| 
		 200mV
	 | 
	
		 ±(1.0%+25)
	 | 
	
		 0.1mV
	 | 
	| 
		 2V
	 | 
	
		 ±(0.8%+25)
	 | 
	
		 1mV
	 | 
	| 
		 20V
	 | 
	
		 10mV
	 | 
	| 
		 200V
	 | 
	
		 100mV
	 | 
	| 
		 750V
	 | 
	
		 ±(1.2%+25)
	 | 
	
		 1V
	 | 
	 Input impedance: 
	 200mV range: 1MΩ 
	 other ranges:10MΩ;
	 The frequency response of sine wave and triangular wave is 40Hz-1kHz; the frequency response of other waveform is 40Hz-200Hz.
	 Over-range protection: 
	 200mV range: DC 250V or AC peak value. 
	 Other ranges: DC 1000V or AC peak value
	 Displaying: True RMS (true value response) 
	 It’s normal that some range does not turn to “0” and it does not affect the measuring accuracy.
DCA 
	| 
		 Range
	 | 
	
		 Accuracy
	 | 
	
		 Resolution
	 | 
	| 
		 200uA
	 | 
	
		 ±(0.5%+4)
	 | 
	
		 0.01uA
	 | 
	| 
		 2mA
	 | 
	
		 0.0001mA
	 | 
	| 
		 20mA
	 | 
	
		 0.001mA
	 | 
	| 
		 200mA
	 | 
	
		 ±(0.8%+6)
	 | 
	
		 0.01mA
	 | 
	| 
		 20A
	 | 
	
		 ±(2.0%+15)
	 | 
	
		 0.001A
	 | 
	 Max. measuring volt drop: 200mV 
	 Max. input current: 20A (within 10 seconds)
	 Over-range protection: 
	 0.2A/250V fuse on range less than 200mA 
	 20A/250V fast melt fuse on other range.
 NOTE: 
	 20A range: ≤5A , continuous measurement is allowed. 
	 5A~20A: continuous measurement time should be less than 10 sec. Time interval should be more than 5 min.
ACA 
	| 
		 Range
	 | 
	
		 Accuracy
	 | 
	
		 Resolution
	 | 
	| 
		 200mA
	 | 
	
		 ±(1.5%+15)
	 | 
	
		 0.1mA
	 | 
	| 
		 20A
	 | 
	
		 ±(2.5%+35)
	 | 
	
		 10mA
	 | 
	 Max. measuring volt drop: 200mV 
	 Max. input current: 20A (within 10 seconds)
	 Over-range protection: 
	 ≤200mA: 0.2A/250V 
	 20A/250V fast melt fuse
	 Frequency response: (40~200)Hz
	 Displaying: True RMS
	 20A range: ≤5A , continuous measurement is allowed. 
	 5A~20A: continuous measurement time should be less than 10 sec. Time interval should be more than 5 min.
Resistance (Ω) 
	| 
		 Range
	 | 
	
		 Accuracy
	 | 
	
		 Resolution
	 | 
	| 
		 200Ω
	 | 
	
		 ±(0.4%+10)
	 | 
	
		 0.01Ω
	 | 
	| 
		 2kΩ
	 | 
	
		 ±(0.4%+5)
	 | 
	
		 0.1Ω
	 | 
	| 
		 20kΩ
	 | 
	
		 1Ω
	 | 
	| 
		 200kΩ
	 | 
	
		 10Ω
	 | 
	| 
		 2MΩ
	 | 
	
		 100Ω
	 | 
	| 
		 20MΩ
	 | 
	
		 ±(1.2%+25)
	 | 
	
		 1kΩ
	 | 
	| 
		 200MΩ
	 | 
	
		 ±(5%+45)
	 | 
	
		 10kΩ
	 | 
	 Open voltage: less than 3V
	 Overload protection: DC 250V or AC peak value.
 Note: 
	 At range 200Ω, should make the test leads short, and measure the resistance of the wire, then, subtract it from the actual measuring value.
Capacitance 
	| 
		 Range
	 | 
	
		 Accuracy
	 | 
	
		 Resolution
	 | 
	| 
		 20nF/200nF
	 | 
	
		 ±(4.0%+50)
	 | 
	
		 1pF/10pF
	 | 
	| 
		 2uF
	 | 
	
		 100pF
	 | 
	| 
		 20uF
	 | 
	
		 1nF
	 | 
	| 
		 200uF
	 | 
	
		 10nF
	 | 
	| 
		 2000uF
	 | 
	
		 100nF
	 | 
	 Overload protection: DC 36V or AC peak value
Frequency 
	| 
		 Range
	 | 
	
		 Accuracy
	 | 
	
		 Resolution
	 | 
	| 
		 20Hz
	 | 
	
		 ±(0.1%+3)
	 | 
	
		 0.001Hz
	 | 
	| 
		 200Hz
	 | 
	
		 0.01Hz
	 | 
	| 
		 2kHz
	 | 
	
		 0.1Hz
	 | 
	| 
		 20kHz
	 | 
	
		 1Hz
	 | 
	| 
		 200kHz
	 | 
	
		 10Hz
	 | 
	| 
		 2MHz
	 | 
	
		 100Hz
	 | 
	 Input sensitivity: 1.5Vrms.
	 Overload protection: DC 250V or AC peak value (within 10sec.)
hFE 
	| 
		 Range
	 | 
	
		 Scope
	 | 
	
		 Testing condition
	 | 
	| 
		 hFE NPN or PNP
	 | 
	
		 (0~1000)β
	 | 
	
		 Base DC current is approx. 10uA,Vce is approx. 3V
	 | 
Conductance measurement 
	| 
		 Range
	 | 
	
		 Accuracy
	 | 
	
		 Resolution
	 | 
	| 
		 (0.1~100)nS
	 | 
	
		 ± (1.0%+30)
	 | 
	
		 0.1nS
	 |