Search
Log in
Login:
Password:
Register
Forgot your password?

Electronic Loads



ATH-8065 Programmable Electronic Load
ATH-8065 Programmable Electronic Load
Programmable electronic load is designed for the operation as a load when testing, setting and adjusting power blocks, amplifiers, sound reproducers and other radio equipment with supply voltage of up to 500V, load current of up to 30A and accepted power of up to 600 W. Operation modes: CV voltage stabilization, CC current stabilization, CR resistance stabilization, CW power stabilization, 2 combined modes: CC+CV, CR+CW. Protection: current, voltage, power, heat, wrong polarity connection. Soft launch function. Battery test. Dynamic test support with rising / falling edge setting. External triggering support. Voltage drop compensation. Operation per the list. Auto test. USB / RS-232 control. Dimensions: 16.9 x 4.1 x 17,9 in / 428 x 103.5 x 453.5 mm. Weight: 36,8lb / 17.6kg.
 
ATH-8125 Programmable Electronic Load
ATH-8125 Programmable Electronic Load
Programmable electronic load is designed for the operation as a load when testing, setting and adjusting power blocks, amplifiers, sound reproducers and other radio equipment with supply voltage of up to 500V, load current of up to 60A and accepted power of up to 1200 W. Operation modes: CV voltage stabilization, CC current stabilization, CR resistance stabilization, CW power stabilization, 2 combined modes: CC+CV, CR+CW. Protection: current, voltage, power, heat, wrong polarity connection. Soft launch function. Battery test. Dynamic test support with rising / falling edge setting. External triggering support. Voltage drop compensation. Operation per the list. Auto test. USB / RS-232 control. Dimensions: 16.9 x 4.1 x 17,9 in / 428 x 103.5 x 453.5 mm. Weight: 36,8lb / 17.6kg.
 
ATH-8180 Programmable Electronic Load
ATH-8180 Programmable Electronic Load
Programmable electronic load is designed for the operation as a load when testing, setting and adjusting power blocks, amplifiers, sound reproducers and other radio equipment with supply voltage of up to 150V, load current of up to 240A and accepted power of up to 1800 W. Operation modes: CV voltage stabilization, CC current stabilization, CR resistance stabilization, CW power stabilization, 2 combined modes: CC+CV, CR+CW. Protection: current, voltage, power, heat, wrong polarity connection. Soft launch function. Battery test. Dynamic test support with rising / falling edge setting. External triggering support. Voltage drop compensation. Operation per the list. Auto test. USB / RS-232 control. Dimensions: 8,2x16,9x17,9 in / 207x428x453.5 mm. Weight: 69,7lb / 31,6kg.
 
ATH-8185 Programmable Electronic Load
ATH-8185 Programmable Electronic Load
Programmable electronic load is designed for the operation as a load when testing, setting and adjusting power blocks, amplifiers, sound reproducers and other radio equipment with supply voltage of up to 500V, load current of up to 120A and accepted power of up to 1800 W. Operation modes: CV voltage stabilization, CC current stabilization, CR resistance stabilization, CW power stabilization, 2 combined modes: CC+CV, CR+CW. Protection: current, voltage, power, heat, wrong polarity connection. Soft launch function. Battery test. Dynamic test support with rising / falling edge setting. External triggering support. Voltage drop compensation. Operation per the list. Auto test. USB / RS-232 control. Dimensions: 8,2x16,9x17,9 in / 207x428x453.5 mm. Weight: 69,7lb / 31,6kg.
 
ATH-8240 Programmable Electronic Load
ATH-8240 Programmable Electronic Load
Programmable electronic load is designed for the operation as a load when testing, setting and adjusting power blocks, amplifiers, sound reproducers and other radio equipment with supply voltage of up to 150V, load current of up to 240A and accepted power of up to 2400 W. Operation modes: CV voltage stabilization, CC current stabilization, CR resistance stabilization, CW power stabilization, 2 combined modes: CC+CV, CR+CW. Protection: current, voltage, power, heat, wrong polarity connection. Soft launch function. Battery test. Dynamic test support with rising / falling edge setting. External triggering support. Voltage drop compensation. Operation per the list. Auto test. USB / RS-232 control. Dimensions: 8,2x16,9x17,9 in / 207x428x453.5 mm. Weight: 69,7lb / 31,6kg.
 
ATH-8245 Programmable Electronic Load
ATH-8245 Programmable Electronic Load
Programmable electronic load is designed for the operation as a load when testing, setting and adjusting power blocks, amplifiers, sound reproducers and other radio equipment with supply voltage of up to 500V, load current of up to 120A and accepted power of up to 2400 W. Operation modes: CV voltage stabilization, CC current stabilization, CR resistance stabilization, CW power stabilization, 2 combined modes: CC+CV, CR+CW. Protection: current, voltage, power, heat, wrong polarity connection. Soft launch function. Battery test. Dynamic test support with rising / falling edge setting. External triggering support. Voltage drop compensation. Operation per the list. Auto test. USB / RS-232 control. Dimensions: 8,2x16,9x17,9 in / 207x428x453.5 mm. Weight: 69,7lb / 31,6kg.
 
ATH-8311 Programmable Electronic Load
ATH-8311 Programmable Electronic Load
Programmable electronic load. Load operation modes: load current stabilization, resistance stabilization, power stabilization (limitation). Output parameters – Load voltage: 0…360 V; Load current: 0…30 A; power consumption: 300 W). Current stabilization – Setting range: 0.000…2.999 A / 3.00…30.00 A; Setting inaccuracy: (0.2%+3 mA) / (0.2%+30 mA); Setting discrecity: 1 mA / 10 mA. Resistance stabilization – Setting range: 0.01…99.99 Ω/ 100…500 Ω; Setting discrecity: 0.1 Ω / 0.01 Ω. Dimensions: 11.2 x 3.7 x 8.5 in / 285 x 95 x 215 mm. Weight: 10 lb / 4,5 kg.
 
ATH-8360 Programmable Electronic Load
ATH-8360 Programmable Electronic Load
Programmable electronic load is designed for the operation as a load when testing, setting and adjusting power blocks, amplifiers, sound reproducers and other radio equipment with supply voltage of up to 150V, load current of up to 240A and accepted power of up to 3600 W. Operation modes: CV voltage stabilization, CC current stabilization, CR resistance stabilization, CW power stabilization, 2 combined modes: CC+CV, CR+CW. Protection: current, voltage, power, heat, wrong polarity connection. Soft launch function. Battery test. Dynamic test support with rising / falling edge setting. External triggering support. Voltage drop compensation. Operation per the list. Auto test. USB / RS-232 control. Dimensions: 22.6x18.3x14 in / 575x465x355 mm. Weight: 154.3lb / 70kg.