Search
Log in
Login:
Password:
Register
Forgot your password?

ATH-8360 Programmable Electronic Load

Programmable electronic load is designed for the operation as a load when testing, setting and adjusting power blocks, amplifiers, sound reproducers and other radio equipment with supply voltage of up to 150V, load current of up to 240A and accepted power of up to 3600 W. Operation modes: CV voltage stabilization, CC current stabilization, CR resistance stabilization, CW power stabilization, 2 combined modes: CC+CV, CR+CW. Protection: current, voltage, power, heat, wrong polarity connection. Soft launch function. Battery test. Dynamic test support with rising / falling edge setting. External triggering support. Voltage drop compensation. Operation per the list. Auto test. USB / RS-232 control. Dimensions: 22.6x18.3x14 in / 575x465x355 mm. Weight: 154.3lb / 70kg.

Programmable electronic load is designed for the operation as a load when testing, setting and adjusting power blocks, amplifiers, sound reproducers and other radio equipment with supply voltage of up to 150V, load current of up to 240A and accepted power of up to 3600 W.

Main Features:

Specifications:

Input ratings

Power

3600 W

Current

0...240 A

Voltage

0...150 V

CC mode

Range

0...24 A

0...240 A

Resolution

1 mA

10 mA

Accuracy

0.05%set value +0.05%range

0.1% set value +0.05% range

CV mode

Range

0.1...19.999 V

0.1...150 V

Resolution

1 mV

10 mV

Accuracy

0.03%set value +0.02%range

0.03%set value +0.02%range

CR mode

Range

0.03...10 kΩ

0.03...5 kΩ

Resolution

16 bit

16 bit

Accuracy

0.1%set value +0.1%range

0.1%set value+ 0.1%range

CW mode

Range

0...3600 W

0...3600 W

Resolution

1 mW

10 mW

Accuracy

0.1%set value +0.1%range

0.1%set value +0.1%range

Voltage measurement

Voltage

0...19.999 V

0...150 V

Resolution

1 mV

10 mV

Accuracy

0.015%set value+0.03%range

0.015%set value+0.03%range

Current measurement

Current

0...24 A

0..240 A

Resolution

0.1 mA

1 mA

Accuracy

0.03%set value +0.08%range

0.1%set value +0.08%range

Power measurement

Power

100 W

3600W

Resolution

1 mW

10 mW

Accuracy

0.1%set value +0.1%range

0.1%set value +0.1%range

Battery test

Battery voltage: 0.5...120 V; Max. measurable capacity: 999 Ah; Resolution: 0.1 mA

Dynamic test

Operation per the list: switching: 0...25 kHz; 5 A/µs; T1&T2: 60 µs -999 s; Accuracy: ±(15% shift+10% range)

Soft launch; Time

1 ms; 2 ms; 5 ms; 10 ms; 20 ms; 50 ms; 100 ms; 200 ms
Accuracy: ±(15% shift +10% range)

Short circuit

Current (CC)

=26.4 A

= 264 A

Voltage (CV)

0 V

Resistance (CR)

= 8 mΩ

Dimensions

W*H*L (in/mm)

22.6x18.3x14 in / 575x465x355 mm

Weight

lb / kg

154.3lb / 70kg

Compatible Software


AKTAKOM ElectronicLoadPro (AELP)
AKTAKOM ElectronicLoadPro software is designed to control programmable electronic loads from a PC. This software allows to set up input voltage, current, resistance and power as well as supports electronic load advanced functions: dynamic and automatic testing, I-V curve scan, battery testing.

Back to the section